Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters

Database
Language
Document Type
Year range
1.
mSphere ; 7(5): e0025722, 2022 10 26.
Article in English | MEDLINE | ID: covidwho-2053133

ABSTRACT

Accurate, highly specific immunoassays for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) are needed to evaluate seroprevalence. This study investigated the concordance of results across four immunoassays targeting different antigens for sera collected at the beginning of the SARS-CoV-2 pandemic in the United States. Specimens from All of Us participants contributed between January and March 2020 were tested using the Abbott Architect SARS-CoV-2 IgG (immunoglobulin G) assay (Abbott) and the EuroImmun SARS-CoV-2 enzyme-linked immunosorbent assay (ELISA) (EI). Participants with discordant results, participants with concordant positive results, and a subset of concordant negative results by Abbott and EI were also tested using the Roche Elecsys anti-SARS-CoV-2 (IgG) test (Roche) and the Ortho-Clinical Diagnostics Vitros anti-SARS-CoV-2 IgG test (Ortho). The agreement and 95% confidence intervals were estimated for paired assay combinations. SARS-CoV-2 antibody concentrations were quantified for specimens with at least two positive results across four immunoassays. Among the 24,079 participants, the percent agreement for the Abbott and EI assays was 98.8% (95% confidence interval, 98.7%, 99%). Of the 490 participants who were also tested by Ortho and Roche, the probability-weighted percentage of agreement (95% confidence interval) between Ortho and Roche was 98.4% (97.9%, 98.9%), that between EI and Ortho was 98.5% (92.9%, 99.9%), that between Abbott and Roche was 98.9% (90.3%, 100.0%), that between EI and Roche was 98.9% (98.6%, 100.0%), and that between Abbott and Ortho was 98.4% (91.2%, 100.0%). Among the 32 participants who were positive by at least 2 immunoassays, 21 had quantifiable anti-SARS-CoV-2 antibody concentrations by research assays. The results across immunoassays revealed concordance during a period of low prevalence. However, the frequency of false positivity during a period of low prevalence supports the use of two sequentially performed tests for unvaccinated individuals who are seropositive by the first test. IMPORTANCE What is the agreement of commercial SARS-CoV-2 immunoglobulin G (IgG) assays during a time of low coronavirus disease 2019 (COVID-19) prevalence and no vaccine availability? Serological tests produced concordant results in a time of low SARS-CoV-2 prevalence and no vaccine availability, driven largely by the proportion of samples that were negative by two immunoassays. The CDC recommends two sequential tests for positivity for future pandemic preparedness. In a subset analysis, quantified antinucleocapsid and antispike SARS-CoV-2 IgG antibodies do not suggest the need to specify the antigen targets of the sequential assays in the CDC's recommendation because false positivity varied as much between assays targeting the same antigen as it did between assays targeting different antigens.


Subject(s)
COVID-19 , Population Health , Humans , SARS-CoV-2 , COVID-19/diagnosis , COVID-19/epidemiology , Prevalence , Seroepidemiologic Studies , Sensitivity and Specificity , Antibodies, Viral , Immunoglobulin G
2.
Clin Infect Dis ; 74(4): 584-590, 2022 03 01.
Article in English | MEDLINE | ID: covidwho-1709326

ABSTRACT

BACKGROUND: With limited severe acute respiratory syndrome coronavirus (SARS-CoV-2) testing capacity in the United States at the start of the epidemic (January-March 2020), testing was focused on symptomatic patients with a travel history throughout February, obscuring the picture of SARS-CoV-2 seeding and community transmission. We sought to identify individuals with SARS-CoV-2 antibodies in the early weeks of the US epidemic. METHODS: All of Us study participants in all 50 US states provided blood specimens during study visits from 2 January to 18 March 2020. Participants were considered seropositive if they tested positive for SARS-CoV-2 immunoglobulin G (IgG) antibodies with the Abbott Architect SARS-CoV-2 IgG enzyme-linked immunosorbent assay (ELISA) and the EUROIMMUN SARS-CoV-2 ELISA in a sequential testing algorithm. The sensitivity and specificity of these ELISAs and the net sensitivity and specificity of the sequential testing algorithm were estimated, along with 95% confidence intervals (CIs). RESULTS: The estimated sensitivities of the Abbott and EUROIMMUN assays were 100% (107 of 107 [95% CI: 96.6%-100%]) and 90.7% (97 of 107 [83.5%-95.4%]), respectively, and the estimated specificities were 99.5% (995 of 1000 [98.8%-99.8%]) and 99.7% (997 of 1000 [99.1%-99.9%]), respectively. The net sensitivity and specificity of our sequential testing algorithm were 90.7% (97 of 107 [95% CI: 83.5%-95.4%]) and 100.0% (1000 of 1000 [99.6%-100%]), respectively. Of the 24 079 study participants with blood specimens from 2 January to 18 March 2020, 9 were seropositive, 7 before the first confirmed case in the states of Illinois, Massachusetts, Wisconsin, Pennsylvania, and Mississippi. CONCLUSIONS: Our findings identified SARS-CoV-2 infections weeks before the first recognized cases in 5 US states.


Subject(s)
COVID-19 , Population Health , Antibodies, Viral , COVID-19/diagnosis , Enzyme-Linked Immunosorbent Assay , Humans , Immunoglobulin G , SARS-CoV-2 , Sensitivity and Specificity
SELECTION OF CITATIONS
SEARCH DETAIL